Wastewater station Aqualift F for wastewater with and without sewage for underground installation
Functions
Lifting station for wastewater with and without sewage
Draining function, for use after a pipe burst or flooding
Chamber ready for installation, also suitable for installation in impermeable concrete
Application
Can be used as a lifting station according to DIN EN 12056-4 for wastewater with sewage for draining spots underneath the backwater level.
Installation advantage
Toolless pump removal
Installation in impermeable concrete The KESSEL gasket set guarantees safe sealing against water pressure even if the wastewater station is installed in impermeable concrete.
Draining function The drain integrated in the cover collects washwater. Even in the event of a pipe burst or flooding, the pump discharges this washwater continually over the backwater level, keeping cellar rooms dry.
Maximum safety through SDS switch unit The intelligent switch unit (for Tronic and Duo versions) with integrated self-diagnosis system SDS and battery buffering continually monitors all electrical components and keeps an electronic operating log that can be read out. The pump is put into operation briefly once a week.
Installation in impermeable concrete - seal set for protection from water load The KESSEL gasket set (Art. no. 83 023) guarantees safe sealing against water load even when Aqualift® F is installed in impermeable concrete.